Remote Wet-to-Wet Differential Pressure Sensor

Higher Reliability, Faster Installation, Superior Accuracy | Sense the Difference
Revolutionary design eliminates plumbing/bypass assemblies
16 selectable differential ranges in one device
LCD display for verification of high, low, and differential pressures
Swap or replace remote sensors with ease

  • Drastically reduce plumbing needs and save installation time
  • Order with pre-fabricated wireor pre-fabricated bypass assembly
  • Single device for 1-500 PSID makes ordering easy
  • Swap or replace remote sensors with ease
  • LCD and dip switches make configuration fast and simple
  • Remote sensors come standard with DIN43650 connection for easy plug-and-play, no wire twisting
    MEMS sensor technology
  • Integrated surge snubber protects sensor from water hammer for reliable long term performance
  • Manual and remote zero for maintained accuracy
  • Port swap corrects plumbing errors
  • Uni/bi directional
  • Conduit and wire connection compatible

Ask for a quotation

The PW30 Series uses remote sensors to eliminate the need for costly bypass assemblies, enabling fast, cost effective installation. The remote sensors mount directly to pipe to eliminate bleeding and additional plumbing. Optional factory pre-wired harnesses also available in wire and armored cable versions. NEW! Order pre-fabricated with a 3 or 5-valve bypass assembly for easy bleeding and installation where bypass is required. Standard LCD screen and dip switches make configuration a breeze. Measure 16 differential pressure ranges from 1-500 PSID with a single device without sacrificing accuracy. Selectable output 0-5V, 0-10V, or 2 Wire 4-20mA.

  • Demand measurement in HVAC systems for pump speed control and local indication
  • Process control systems
  • Flow measurement of gases, vapors, and liquids compatible with 316L SS
  • Filter status monitoring
  • System leak detection
  • Great for data center wet pressure sensing
Power supply

Voltage output mode (0-5v)
Voltage output mode (0-10v)
Current (4-20mA) output mode

12-30VDC/24VAC1 20mA max.
13-30VDC/24VAC1 required for 10V FS output
15-30VDC (0 Ohm)/16-30VDC (250 Ohm)/
18-30VDC (500 Ohm) , 20mA max.

Outputs

Switch selectable

2-wire 4-20mA, 3-wire 0-5V/10V

Operating Temperature

Transmitter

-22 to 158°F (-30 to 70°C)

Media Compatibility

Type

Temperature

Water, other 316 SS compatible media (316L diaphragm)

32 to 250°F (0-125°C)

Zero adjustment

Automatic

Pushbutton, terminal block switch input
Press button for 5 seconds to re-zero
Hold for 10 seconds to restore factory settings

Sensor Type

Micro-machined silicon strain gauge

PW Transmitter Accuracy2

Sensor PSIG
25 PSIG
50 PSIG
100 PSIG
250 PSIG
500 PSIG

2% Accuracy Ranges
0-1 / 0-2 PSID
0-10 / 0-15 PSID
0-15 / 0-20 / 0-25 / 0-30 PSID
0-30 / 0-40 / 0-50 PSID
0-75 / 0-100 / 0-125 PSID

1% Accuracy Ranges
0-5 / 0-10 / 0-15 / 0-20 / 0-25 PSID
0-20 / 0-25 / 0-30 / 0-40 / 0-50 PSID
0-40/ 0-50 / 0-75 / 0-100 PSID
0-75 / 0-100 / 0-125 / 0-150 / 0-250 PSID
0-150 / 0-250 / 0-500 PSID

Sensor Performance

Accuracy3
Stability (1 year)
Over-range protection
Pressure Cycles
Compensated Operating Range
Temperature Compensation
%FS/C
Vibration

< ±0.25% BFSL ±0.25% FS, typ 200% rated pressure > 100 Million
14 to 158°F (-10-70°C)
Zero, <±0.03(<100kPa), <±0.02(>100kPa)
Span, <±0.03(<100kPa), <±0.02(>100kPa)
10G peak, 20 to 2000 Hz

Enclosure

PW30M
PW30W
PWT [xxx]

Construction
Rating
Construction
Rating
Construction

Powder coated steel (metal)
Nema 3R (Metal), IP65
PC/ABS (Plastic)
Nema 4X (plastic), IP65
Stainless Steel, 304, 1/4” MNPT, 1/2” Conduit Fitting

(1) One side of transformer secondary is connected to signal common. Dedicated transformer is recommended.

(2) FS is defined as the full scale of the selected range. Accuracy includes non-linearity, hysteresis, and repeatability.

(3) Because of lower accuracy, it is not factory recommended to use an output range less than 10% of the total sensor PSIG.